Error Codes
© Hirschmann Rev. I 05/22/17 190154_I.DOC
The number of the
selected File base
and the
programmed value
are not identical
No valid data in the load
chart file
Upload valid load chart
file
Base number not
programmed
Program the correct base
number (1 for base 1, 2
for base 2)
Load chart file wrongly
programmed
Check base programming
in the load chart file.
Error in the CAN
bus data transfer for
all CAN units
CAN Bus cable between
the central unit and the
sensor unit defective or
not connected.
Check the connection
between the central unit
and the sensor units
Can bus port in the
central unit defective
Replace the central unit
Short circuit in a CAN Bus
cable
Error in the can bus
data transfer of the
pressure transducer
sensor unit
Cable between the
central unit and the
sensor unit defective.
Check the cable to the
sensor unit
Can bus port in the
central unit defective
Replace the central unit
Can bus port in the
sensor unit is defective
Replace the sensor unit
Sensor unit is defective
Replace the sensor unit
Error in the can bus
pressure transducer
sensor unit
The analog values of the
sensor unit are invalid
Replace the sensor unit
Error in the can bus
data transfer of the
length/angle sensor
unit
Error in the can bus
length/angle sensor
unit
Error in the can bus
data transfer of the
2
nd
length/angle
sensor unit
Error in the can bus
of the 2
nd
length
/angle sensor unit
Error in the can bus
data transfer of the
force sensor unit
Error in the can bus
force sensor unit