EasyManua.ls Logo

Hirschmann PAT IFLEX5 - Error Codes E80-E89

Hirschmann PAT IFLEX5
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual iFLEX5
© Hirschmann Rev. I 0522/17 190154_I.DOC
68
Error Code
Error
Cause
Elimination
E80
Error in the slewing
angle measurement
The difference between
the average of the
slewing angle and one of
the wipers of the slewing
potentiometer is out of
the tolerance
Check the slewing
potentiometer adjustment
Replace slewing angle
sensor
E82
Error boom control
task
The boom control task is
not running
Restart the system
Load the boom control
task
E84
Wrong rigging
condition.
The selected rigging
condition is not contained
in the crane data file.
Select another rigging
condition
Check the programming
in the crane data file.
E85
Error in the radius
determination
The computed radius is
too small (negative
deflection)
Check the programming
in the crane data file.
E89
Operating mode
switchover with
load.
The operating mode on
the console has been
switched over with the
boom loaded.
Select operating mode
without load on the boom

Table of Contents