Error Codes
© Hirschmann Rev. I 05/22/17 190154_I.DOC
69
Error Code
Error
Cause
Elimination
E91
No data trans-
mission form the
console to the
central unit
24 V supply of the
console is interrupted
Check 24 V at terminal
X1 of the console
electronics
Interruption or accidental
ground in the line
between console
electronics and central
unit
Check the connection
console electronics -
central unit. In case of an
accidental ground, the
transmitter module of the
console electronics might
be damaged. Therefore,
replaces the console
electronics.
Transmitter/receiver
module is defective
Exchange console
electronics or LMI main
board resp.
E92
Error in the data
transmission from
console to central
unit
Loose connection in the
line between console
electronics and central
unit
Transmitter/receiver
module is defective
Check the connection
between console
electronics and central
unit
Exchange console
electronics or LMI main
board resp.
E93
Error in the data
transmission from
the central unit to
the console
refer to E92
refer to E92
E94
No data trans-
mission from the
central unit to the
console
Interruption or accidental
ground in the line central
unit console
Check line to the console
(in case of accidental
ground, replace console
electronics, too).
5 V supply of the
computer in the central
unit is missing
Check connection to the
power unit
5 V supply is too low
Exchange the LMI main
board
Transmitter/receiver
module is defective
Replace console
electronics or LMI main
board
Computer module is
defective
Replace processor board.
Electro-magnetic
interferences (e.g. when
switching contactors or
valves)
Eliminate the source of
interferences by inverse
diodes or varistors.

Table of Contents