Error Code
Error
Cause
Elimination
E95
Error in the console
File
The console File is
defective.
Replace the console File
E96
Error in the internal
RAM of the console.
The CPU of the console
is defective.
The console main board
is defective.
Replace the CPU of the
console
Replace the console main
board.
E97
Error in the external
RAM of the console
The external RAM of the
console is defective.
The console main board
is defective.
Replace the external
RAM of the console.
Replace the console main
board.
E98
LMI watchdog
activated
LMI processing time limit
exceeded
Reset system
Connect PC terminal and
watch error messages
EAB
Short circuit in the
A2B switch circuit
Short circuit in the A2B
switch
Short circuit in the cable
to the A2B switch
Replace A2B switch
Replace cable to the A2B
switch
EAC
A2B switch circuit
disconnected
Disconnected cable in the
A2B switch
Disconnected cable to the
A2B switch
Connect or replace cable
in the A2B switch
Connect or replace cable
to the A2B switch
EAD
No valid A2B switch
status
Sensor wrong function
CAN bus delay
Replace A2B switch
Replace cable to the A2B
switch
EC0
Prohibited area
Boom is about to collide
with the engine hood,
switch off
Move boom to permitted
area
Check values in the data
prom DGA 11.5.
EC1
Approaching
prohibited area
Boom is about to collide
with the engine hood,
prewarning
Move boom to permitted
area
Check values in the data
prom DGA 11.5.
EC2
Angle range of
luffing jib exceeded
Luffing jib is raised too far
Luff down the jib to a
angle specified in the load
chart.