Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 102/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1114
broken wire
Sensor Error: IOPin-
ning5
Locking pin initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1214
circuit ground
1314
circuit battery
1414
module error
1514
output deactivated
1614
error +UB
1714
data error / CAN error
1814
timeout / CAN timeout
1914
safety error
1A14
parameter error
1B14
unspecified error
1C14
missing adjustment
1115
broken wire
Sensor Error: IOPin-
ning6
Locking pin initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1215
circuit ground
1315
circuit battery
1415
module error
1515
output deactivated
1615
error +UB
1715
data error / CAN error
1815
timeout / CAN timeout
1915
safety error
1A15
parameter error
1B15
unspecified error
1C15
missing adjustment
1116
broken wire
Sensor Error: IOPin-
ning7
Locking pin initialization
failure or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1216
circuit ground
1316
circuit battery
1416
module error
1516
output deactivated
1616
error +UB
1716
data error / CAN error
1816
timeout / CAN timeout
1916
safety error
1A16
parameter error
1B16
unspecified error
1C16
missing adjustment

Other manuals for Hirschmann qSCALE i2