© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 104/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
111A
broken wire
Sensor Error: IOInput3
Faulty Input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
121A
circuit ground
131A
circuit battery
141A
module error
151A
output deactivated
161A
error +UB
171A
data error / CAN error
181A
timeout / CAN timeout
191A
safety error
1A1A
parameter error
1B1A
unspecified error
1C1A
missing adjustment
111B
broken wire
Sensor Error: IOInput4
Faulty Input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
121B
circuit ground
131B
circuit battery
141B
module error
151B
output deactivated
161B
error +UB
171B
data error / CAN error
181B
timeout / CAN timeout
191B
safety error
1A1B
parameter error
1B1B
unspecified error
1C1B
missing adjustment
111C
broken wire
Sensor Error: IOInput5
Faulty Input or input
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
121C
circuit ground
131C
circuit battery
141C
module error
151C
output deactivated
161C
error +UB
171C
data error / CAN error
181C
timeout / CAN timeout
191C
safety error
1A1C
parameter error
1B1C
unspecified error
1C1C
missing adjustment