Appendix
© 2016 Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com 144/161
qSCALE i2 Cranes (Tool Version 3.0.34) Service Manual / Issue B / 11-2017 / ac.
Error
Code
Description
Cause
Notice/Solution
1198
broken wire
Actuator Error: IOEna-
bleOutrigger
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1298
circuit ground
1398
circuit battery
1498
module error
1598
output deactivated
1698
error +UB
1798
data error / CAN error
1898
timeout / CAN timeout
1998
safety error
1A98
parameter error
1B98
unspecified error
1C98
missing adjustment
1199
broken wire
Sensor Error:
IOBypOutrigger
Faulty system override
switch or input module is
defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
1299
circuit ground
1399
circuit battery
1499
module error
1599
output deactivated
1699
error +UB
1799
data error / CAN error
1899
timeout / CAN timeout
1999
safety error
1A99
parameter error
1B99
unspecified error
1C99
missing adjustment
119F
broken wire
Actuator Error: unspeci-
fied
Output error or output
module is defective
Check the CAN connections and wiring, the
sensor calibration, and the CAN configura-
tion. Invalid sensor swap
129F
circuit ground
139F
circuit battery
149F
module error
159F
output deactivated
169F
error +UB
179F
data error / CAN error
189F
timeout / CAN timeout
199F
safety error
1A9F
parameter error
1B9F
unspecified error
1C9F
missing adjustment