Appendix 
© 2016   Hirschmann Automation and Control GmbH · Mobile Machine Control Solutions · www.beldensolutions.com    46/57 
qSCALE i2 Cranes (Tool Version 3.0.34) Operators Manual / Issue B / 11-2017 / ac. 
5.1.2  DIO Extension cSCALE DX-66-AM0 
608785 
Dimensions .................. 238.5 mm (W) x 211 mm (H) x 67 mm (D) 
Housing ........................ cast aluminium alloy housing, blue  
Gore-Tex
®
 membrane for venting 
Mounting ....................... in/outside, mounting accessories not included 
Temperature Range ..... -40 up to +70 °C / -22 up to +158 °F (operation) 
-40 up to +85 °C / -40 up to +185 °F (storage) 
Protection Class .......... IP66/67 /optional IP69k according to EN 60529 
EMC ............................... EN 13000, EN 61000-6-2:2005; EN 61000-6-4:2007  
Climatic Conditions ..... HAC Standard for Extended Environment Conditions 
Salt Mist ........................ Merchant Navy (GL, ABS, DNV, BV, LRS) 
Sinusoidal Vibrations .. DIN EN 60068-2-6 2008  
Vibration e.g. 10m/s
2
, 8.5-150Hz. 1 oct/min, 10 cycles/axis 
Broadband noise ......... EN 50155:2007 (rail requirements), DIN EN 60068-2-64 (environmental 
testing) e.g. 10 Hz <= f <= 150 Hz; Broadband Noise: 8.5 m/s
2
;  
30min / axis; functional test after test of each axle; 
DIN EN 60068-2-27 shocks (02 – 2008)e.g. shocks 150 m/s
2
 peak, 11 ms, 
half-sine, in each of three mutually axis; 6 shock/axes; 
ROHS Compliance ....... Yes 
 
Operating voltage   voltage range     6 up to 36 V
DC
 
Protection  Inverse polarity protection  up to -36 V
DC
 
 
CAN  1x CAN-Interface  
according to ISO 11898, CAN-specification 2.0 B active,  
up to 1 Mbit/s (default 125 Kbit/s) 
I/Os  8x  AI (4…20 mA) 
6x  DI 
2x  DI_DIAG (diagnosis capable) 
4x  DI_HSC (high speed counter) 
4x  DO (1A) 
4x  DO_PWM (2A)