6.4.2 Operating Temperature Too High / Too Low
Operating temperature
Too High / Too Low
Does the IJ printer
temperature indication agree
with the ambient
temperature?
Is the EZJ106 board CN7
connector disconnected?
Connect the connector.
Yes
No
Yes
No
Replace the EZJ106 board.
Is the operating temperature
upper-/lower-limit value
erroneously set?
Properly set the operating
temperature upper-/lower-limit
value.
Use an air-conditioner or the like
to ensure that the IJ printer
ambient temperature is within
the operating temperature range.
No
Yes
Is the problem
fixed?
No
Yes
Replace the print head.
END
Is the problem
fixed?
No
Yes
Replace the EZJ93 board.