EasyManua.ls Logo

Hitachi NAS Platform 4000 Series - Configuring the Replacement Servers

Hitachi NAS Platform 4000 Series
129 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ite
m Labels Ports Connections
3 1 Storage or FC switches
2 Storage or FC switches
3 Storage or FC switches
4 Storage or FC switches
4 0 Customer facing management network
5 1 Private management Ethernet network
5. If cables are not labeled, label them befor
e removing them from the server.
6. Remove all cables from the server, and remove the server from the rack.
7. Remove the rail mounts from the old server, and install them on the new server.
8. Remove the battery from the old server, and install it in the new server.
9. Remove the bezel from the old server, and install it on the new server.
10. Insert the new server into the rack, and connect the power cords to the power
supplies.
Note: Do not make any other cable connections at this time.
Configuring the replacement servers
Before you begin
Obtain the necessary IP addr
esses to be used for the replacement server. Servers
shipped from the factory have not yet had the nas-precong script run on them, so a
r
eplacement server will not have any IP addr
esses pre-congured for your use. You need
IP addresses for the following:
Eth1 (cluster IP)
Eth1 (testhost private IP)
Eth0 (testhost external IP)
192.0.2.200/24 eth1 (cluster IP)
192.0.2.2/24 eth1 (testhost private IP)
192.168.4.120/24 eth0 (testhost external IP, which might vary)
On a replacement server:
Conguring the replacement servers
Appendix A: Server replacement procedures
Hitachi NAS Platform and Hitachi Unied Storage Series 4000 Hardware Reference 120

Table of Contents

Related product manuals