Table 22 Server status - model HNAS 4040
Server status LED Meaning
Amber Critical failure and server is not
oper
ational.
Slo
w green ash (every three
seconds)
System has been shut down and you can
remove the power.
Medium green ash (every .8
seconds)
Server needs attention, and a non-critical
failure has been detected. For example, a
fan or power supply has failed.
O Normal operation.
Table 23 Server status - models HNAS 4060, 4080, and 4100
Server status LED Meaning
Solid green System has rebooted and the server is
online.
Slow green ash (every three
seconds)
System has been shut down and you can
r
emo
ve the power.
Medium green ash (every 1.3
seconds, with the server online)
No enterprise virtual server (EVS) residing
on the server.
Medium green ash (every .8
seconds)
Server is available.
Fast green ash (5 times per second) Server is booting.
6. If the gr
een LED is ashing 5 times per second, plug in the serial cable.
If the terminal screen is gener
ating output, let the process complete.
If the terminal screen is blank, press the Reset button.
Note: Pulling the po
wer cor
d from the server is not recommended.
Do not pull the power cord unless it is absolutely necessary. First,
complete the steps above.
Powering down the server for shipment or storage
Follo
w this pr
ocedure whenever a server is to be powered down and will be left o
for
mor
e than a day. If the system is being restarted or power-cycled, this procedure is not
required.
Powering down the server for shipment or storage
Chapter 6: Rebooting, shutting down, and powering o