Before replacing a component that is not
hot-swappable, you must shut do
wn and power
o the server. See
Rebooting or shutting down a server (on page 80) for details.
The HNAS 4040
model includes the follo
wing hot-swappable components:
■
HDDs
■
PSUs
■
NVRAM battery backup packs
■
Fan assemblies
The HNAS 4060, 4080, and 4100 models includes the following hot-swappable
components:
■
HDDs
■
PSUs
■
NVRAM battery backup packs
■
Fan assemblies
■
SFP+ port adapters
Removing and replacing the front bezel
To access some server components, or eld replaceable units (FRUs), you must rst
remove the front bezel. Replace the bezel after the part replacement is complete.
Bezel removal
The server be
zel is held onto the server chassis through a friction t onto four retention
posts, which are mounted to the chassis along the left and right edges of the chassis.
There are no screws or other fasteners.
Figure 27 Server front plastic bezel with grasping areas
Removing and replacing the front bezel
Chapter 5: Replacing server components
Hitachi NAS Platform and Hitachi Unied Storage Series 4000 Hardware Reference 64