5. Navigate to Home > Server Settings > License Keys
to check the license keys to
ensure you have the correct set of new license keys.
Shutting down the server you are replacing
On the server that you are replacing:
Procedure
1. From the server console, issue the command: shutdown --ship --powerdown
Wait until the console displays Information: Server has shut down, and the
rear panel LEDs turn o. The PSU and server fans continue to run until you remove
the po
wer cables fr
om the PSU module. See the appropriate system component
section for more information.
Note: This specic
powerdown command prepares the system for both
shipping, and potential long-term, post-replacement storage.
2. Unplug the power cor
ds from the power supplies.
3. Wait approximately 15 seconds, and then conrm the NVRAM status LED is o.
If the LED is ashing or xed, press and hold the reset button for ve seconds until
the LED starts ashing. The battery disables when you release the reset button.
4. Use the following rear panel gure and table to identify and label the cabling
placement on the existing server.
Shutting down the server you are replacing
Appendix A: Server replacement procedures
Hitachi NAS Platform and Hitachi Unied Storage Series 4000 Hardware Reference 92