d. Save to a location on your computer.
e.
V
erify that the archive le can be opened and the contents can be extracted.
f. If the archive le contains the words "MISSING_FILES", repeat step 6. If this
does not resolve the issue, then check that both nodes are fully operational
and resolve any issues identied before repeating the procedure.
Resetting the battery age and restarting the chassis monitor
Reset the battery age and Restart the Chassis Monitor as necessary.
Procedure
1. Connect a serial cable to the serial port of the node with the new battery.
2. Open a putty application and set up a serial console session.
a. Select the Serial Radio button.
b. Enter the COM port that your serial dongle is using.
c. Enter 115200 in the Speed box.
d. Click Serial in the Category Tree on the left.
e. Make sure the Speed is 115200.
f. Set the Data bits to 8.
g. Set the Stop bits to 1.
h. Set the Parity to None.
i. Set the Flow Control to None.
j. Click Session in the Category Tree on the left.
k. Enter SMU serial (or similar) in the Saved Sessions box.
l. Click Save.
3. Turn on the putty session logging.
a. Click Logging from the Category Tree on the left.
b. Select Printable output in Session logging.
c. Set the location for the putty output le.
d. In the section What to do if the log le already exists, select Ask the user
every time.
e.
Click Session from the Category Tree on the left, which returns you to the
Session window.
f. Click Save.
4. Click Open to open the session to the Node console.
a. Login as Username: manager Password:nasadmin
5. Type the command ipaddr and verify that you are connected to the correct node.
6. Perform ONLY ONE of the following procedures.
If the node rmware is below 11.1.3225.02, perform the following procedure:
a.
Type the command: new-battery-fitted --field --confirm
Resetting the battery age and restarting the chassis monitor