Humidity:
Oper
ational: 20-80%
Stor
age: 10-90%
Transit: 5-95%
Noise: A-weighted Sound Power Level, Lwa (db re 1pW):
Typical: 71
Max: 81
Shock and vibration:
Optional random vibration: 10 to 350 Hz @ 0.18 Grms
Non-operational sinusoidal vibration: 60 to 350 Hz: @ 1g
Non-operational shock: 3g 11ms, half sine
Packaged transport specication:
Drops fr
om 356mm and 508mm as per ASTM D5276
Vibration at up to 0.53 Grms as per ASTM D4728
Altitude:
Maximum of 2000 meters
Ventilation
There are vents and fan openings on the front and the rear of the server. These openings
are designed to allow airow, which prevents the server from overheating.
Note: At least four inches of clear
ance must be pr
esent at the rear of the
server rack so that airow is unrestricted.
Caution:
Do not place the server in a built-in installation unless pr
oper ventilation is
pr
ovided.
Do not operate the server in a cabinet whose internal ambient temperature
exceeds 35º C (95º F).