Table 20 Host setting values
Terminal Requirement
Connection Crossover (null modem) cable
Emulation VT100
Baud rate 115,200 Bps
Data bits 8
Stop bits 1
Parity None
Flow control None
Note: Once the initial setup has been completed, disconnect the serial cable.
If you need to manage the server thr
ough a serial connection, connect to the
serial port on the e
xternal SMU and use SSH to access the server's CLI. If your
system does not include an external SMU, connect to the server’s embedded
SMU and use SSH to access the server's CLI.
10/100/1000 Ethernet management ports
The 10/100/1000 Ethernet management ports ar
e used to connect the server or node to
the customer facing management network and the private management network, or to
connect dir
ectly to another device for management purposes.
The 10/100/1000 Ethernet ports operate at speeds of up to one (1) gigabit per second,
and require the use of a standard RJ45 cable connector. Once connected, each GE port
has two indicator LEDs; one on the top left and the second on the top right of the port.
These LEDs provide link status and network activity status information as described in
the next table:
Left LED - Speed
Right LED - Link/
Activity Meaning
O Yellow
(ashing)
10 Mbps link present
Green
(not ashing)
Yellow
(ashing)
100 Mbps link present
Orange
(not ashing)
Yellow
(ashing)
1 Gbps link present
O O No link
10/100/1000 Ethernet management ports
Chapter 4: Hitachi NAS Platform server components
Hitachi NAS Platform and Hitachi Unied Storage Series 4000 Hardware Reference 61