EasyManua.ls Logo

Hitachi PH - Page 245

Hitachi PH
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-33 Excitation Setting Adjustment
Press Abort .
The "Excitation V update" screen then opens.
9
Input the optimum value in the "Excitation V-ref.."
The optimum set value is the center value in the good printing range.
10
To complete the set value update, press Back and return to
the "Maintenance menu" screen.
11
During the nozzle characteristic test, the condition of ink particle
generation may deteriorate depending on the excitation V-ref., and
an abnormality such as "Ink Drop Charge Too High" may arise and
stop the ink. In such a case, clean the print head and then eject
the ink again.
During the nozzle property test, the continuous printing mode
becomes invalid. You can print only once by inputting a signal
once.
During the nozzle property test, the product speed matching
setting becomes invalid. Character width may be different from
the reality.
CAUTION
Shut
down
Manual
Back
Show
cursor
Decre-
ment
Incre-
ment
1234567890
Nozzle test
Excitation V update Status: Standby
[ 1 ] (0~19)
Ref. ambient temperature 23 (
)
Automatic update [ 2 ] (0:disable 1:Decrement 2: )
Incremental change [ 1 ] (1-9)
1
Excitation V-ref.
Perform nozzle property test and find the optimum
excitation voltage value.
Increment

Table of Contents