6-20 ● Transmission Sequences
6.4.4 Print Condition Transmission
6.4.4-1 Text
(1) Column count setup (overall)
ESC Header 2BH 30H
● Overall column setup (column count and print format standardization) is
performed.
● The overall column setup must be transmitted independently. It cannot be sent
together with the print format, print specifications, or printings.
(2) Print specifications
● Character height
ESC Header 30H Tens position Units position
Character height (00 to 99)
Actual data must be set
using ASCII codes.
● Character width
ESC Header 31H
Hudreds
position
Tens position Units position
Character width( 000 to 199)
● Character orientation
ESC Header 32H Units position
Character orientation (0 to 3)
● Repeat intervals
ESC Header 34H
Thousands
position
Hudreds
position
Tens position Units position
Repeat intervals (0000 to 9999)
● Repeat count
ESC Header 35H
Thousands
position
Hudreds
position
Tens position Units position
Repeat count (0000 to 9999)
● Print start delay
ESC Header 33H
Thousands
position
Hudreds
position
Tens position Units position
Print start delay (0000 to 9999)
● Print start delay (reverse)
ESC Header 36H
Thousands
position
Hudreds
position
Tens position Units position
Print start delay (reverse) (0000 to 9999)
● Target sensor timer
ESC Header 37H
Hudreds
position
Tens position Units position
Target sensor timer (000 to 999)