6-20 Transmission Sequences
6.4.4 Print Condition Transmission
6.4.4-1 Text
(1) Column count setup (overall)
ESC Header 2BH 30H
Overall column setup (column count and print format standardization) is
performed.
The overall column setup must be transmitted independently. It cannot be sent
together with the print format, print specifications, or printings.
(2) Print specifications
Character height
ESC Header 30H Tens position Units position
Character height (00 to 99)
Actual data must be set
using ASCII codes.
Character width
ESC Header 31H
Hudreds
position
Tens position Units position
Character width( 000 to 199)
Character orientation
ESC Header 32H Units position
Character orientation (0 to 3)
Repeat intervals
ESC Header 34H
Thousands
position
Hudreds
position
Tens position Units position
Repeat intervals (0000 to 9999)
Repeat count
ESC Header 35H
Thousands
position
Hudreds
position
Tens position Units position
Repeat count (0000 to 9999)
Print start delay
ESC Header 33H
Thousands
position
Hudreds
position
Tens position Units position
Print start delay (0000 to 9999)
Print start delay (reverse)
ESC Header 36H
Thousands
position
Hudreds
position
Tens position Units position
Print start delay (reverse) (0000 to 9999)
Target sensor timer
ESC Header 37H
Hudreds
position
Tens position Units position
Target sensor timer (000 to 999)

Table of Contents