1-42 Connection of signals
The output transistor (Tr) is of an open collector type. It operates as indicated below.
Online : Tr ON
Offline : Tr OFF
The voltage and current used by the external device must meet the following
specifications.
IL
20mA (VCE : TYP0.6V, MAX2V)
The IL maximum permissible current is 50 mA.
Vd
DC30V
1.5.3-10 Online signal output
Connection of signals outputted to the outside when the IJ printer is online.
(a) Wiring
Load
TB1
17
13
Online
GND
If a relay, solenoid, or other inductive load is employed, connect a
counterelectromotive force generation prevention diode in parallel with the load.
The load circuit is for DC only. It cannot be used with an AC load.
Output specifications
Vd
GND
IL
TB1
17
13
V
CE
GND
Tr
+12V
External device IJ printer