EasyManuals Logo

Honeywell 200 Series User Manual

Honeywell 200 Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
SECTIONII.
OPERATOR'S
CONTROL
PANEL
4.
The
central
processor
cycle
counter
is
reset;
5.
The
memory
address
register
(MAR)
and
the
memory
local
register
(MLR)
and
their
associated
displays
(i.
e.,
ADDRESS
and
CONTENTS,
respectively)
are
cleared
to
zeros;
6.
The
system
is
set
to
the
two-character
addressing
mode;
7.
Item-mark
trapping
is
reset;
8.
All
interrupt
demands
and
peripheral
interrupt
allow
functions
are
turned
off;
and
9.
An
"initialize"
signal
is
sent
to
all
peripheral
controls
causing
them
to
re-
lease
read/write
channels,
to
clear
stored
instructions,
to
clear
error
indicators,
to
inhibit
interrupts
during
initialization,
and
to
assume
the
following
states:
Printer
Control
Tape
Control
Card
Reader
and/
or
Punch
Control
Same
response
as
to
local
"clear,"
plus
error
indicator
reset.
Error
indicators
reset.
Stored
instruction
cleared,
error
indicators
reset,
"alphanumeric"
mode
entered.
The
operator
should
exercise
caution
in
using
the
INITIALIZE
button
following
machine
stop
conditions
(e.
g.,
error-check
conditions,
program
or
machine
malfunctions,
etc.).
It
is
extremely
important
that
the
operator
use
discretion
in
clearing
error-check
conditions
and
performing
restart
procedures.
If
the
INITIALIZE
button
is
depressed
at
any
time
during
the
operation
of
the
program
or
during
either
a
normal
or
abnormal
stop
condition,
the
resulting
eight
conditions
outlined
above
may
destroy
pertinent
program
information.
In
such
an
event,
it
may
be
necessary
to
rerun
the
program
from
the
beginning.
RUN
Button
The
RUN
button
is
illuminated
when
the
system
is
in
the
RUN
mode
and
turned
off
when
in
or
waiting
to
enter
the
STOP
mode.
The
RUN
mode
can
be
entered
by
depressing
the
RUN
button,
unless
a
parity
check
or
program
check
is
stored.
A
stored
check
must
be
cleared
before
the
RUN
button
is
effective.
Depressing
the
RUN
button
causes
the
AC
OFF
and
RESET
DC
OFF
switches
to
be
overridden
when
the
central
processor
is
energized
and
no
check
conditions
exist.
In
the
RUN
mode,
the
system
executes
(without
manual
intervention)
stored
program
in-
structions
under
control
of
the
sequence
register.
INSTRUCT
Button
2-7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 200 Series and is the answer not in the manual?

Honeywell 200 Series Specifications

General IconGeneral
BrandHoneywell
Model200 Series
CategoryDesktop
LanguageEnglish

Related product manuals