I
6.
SECTION
II.
OPERATOR'S
CONTROL
PANEL
When
a
program
check
occurs.
This
is
not
a
normal
stop
condition
(refer
to
page
2-12
for
a
description
of
this
condition).
After
an
abnormal
stop,
the
program
generally
cannot
be
resumed
successfully
by
simply
depressing
the
RUN
button.
The
operator
may
attempt
to
restart
the
program
at
the
nearest
possible
point
in
the
program
at
which
the
abnormal
stop
occurred.
SY
ST
EM
C
LEAR
Button
This
button
is
effective
only
after
the
STOP
button
has
been
depressed.
When
the
SYSTEM
CLEAR
button
is
depressed,
the
following
conditions
result:
1.
Central
processor
operations
terminate
at
the
end
of
the
current
memory
cycle;
2.
The
RUN
indicator
is
turned
off;
3.
The
central
processor
cycle
counter
is
reset;
4.
The
PARITY
indicator
is
turned
off;
and
5.
The
PROGRAM
indicator
is
turned
off.
Peripheral
operations
are
allowed
to
be
completed,
except
in
the
console
and
the
magnetic
tape
control.
If
data
is
being
transferred
~
the
console
or
tape
when
the
SYSTEM
CLEAR
button
is
depressed,
the
transfer
is
not
completed.
If
data
is
being
transferred
from
the
console
or
tape
when
the
SYSTEM
CLEAR
button
is
depressed,
no
further
information
enters
memory.
However,
tape
movement
continues
until
an
interrecord
gap
is
sensed.
If
an
instruction
is
stored
in
a
peripheral
device,
the
STOP
indicator
does
not
illuminate
after
the
SYSTEM
CLEAR
button
is
depressed.
INITIALIZE
Button
The
INITIALIZE
button
is
effective
only
after
the
STOP
button
has
been
depressed.
When
held
down,
this
switch
causes
all
control
panel
lamps,
except
AC
ON,
AC
OFF,
DC
ON,
RESET
DC
OFF,
VOLTAGE,
FAN,
and
CB
to
illuminate,
thus
providing
a
filament
test.
When
the
INITIALIZE
button
is
released,
only
the
CONTROL
and
SENSE
switch
indicators
remain
illumi-
nated
in
their
original
states:
all
other
indicators
are
turned
off.
Depressing
the
INITIALIZE
button
results
in
the
following
conditions:
1.
The
STOP
indicator
is
illuminated,
and
central
processor
operations
are
terminated
immediately;
2.
Central
processor
stored
instructions
and
subcommands
are
reset;
3.
The
central
processor
parity,
overflow,
and
zero
balance
indicators,
and
other
auxiliary
storage
functions,
are
cleared;
2-6