Appendix F : Galaxy Gold Modem Reset Strings
THE MODEMS LISTED BELOW HAVE BEEN TESTED AND FOUND TO WORK SATISFACTORILY WITH GALAXY GOLD
There is no Guarantee that every combination of Modem and PC will work
Manufacturer Type/Model Comments PC Panel Call Back V21
3Com 3CCM156UK (PCMCIA)
Megahertz 56K Global Modem PC Card
B0X2V0L3E0S12=20S0=0S7=60
Dataflex Design Limited Internal Super Gem (Product Code IM93) F4W0 B0X2V0L3E0S12=20S0=0S7=60
F4 forces the modem to 1200 Baud (CCITT V.22)
W0 forces the modem to only report DTE speed
Digicom K56 Flex To the beginning of the default Modem Reset String add: X3+MS=2, 1, 1200, 2400
Hayes Accura 288 V.34 and Fax – External B0X2V0L3E0S12=20S0=0S7=60
Hayes Accura 336 Message Modem – External B0X2V0L3E0S12=20S0=0S7=60
Hayes Smart Modem Model 07:00038 – External B0X2V0L3E0S12=20S0=0S7=60
Hayes Smart Modem Optima 288 V.FC and Fax – External B0X2V0L3E0S12=20S0=0S7=60
Hayes Accura 56k Speakerphone Modem B0X2V0L3E0S12=20S0=0S7=50S37=5
Hayes Accura V92 15328 Series 0269 B0X2V0L3E0S12=20S0=0S7=60+MS=V22 *V6.8/3.8 are required
Hayes Accura 56k 15400 Series 0269 B0X2V0L3E0S12=20S0=0S7=60+MS=V22 *V6.8/3.8 are required
Lasat Lasat Credit 336 – PCMCIA B0E0L2&G0W0
MR Modem PCMCIA 56K B0X3V0L3E0S12=20S0=0S7=60S37=5
Multi-Tech System Inc MT2834ZDX – External B0X2V0L3E0S12=20S0=0S7=60
Multi-Tech System Inc 56K MT5600ZDXV – External X3+MS=2, 1, 1200, 2400B0X2V0L3E0S12=20S0=0S7=60
Pace PACE Linnet 34 fx +MS=1,0,1200,1200B0X2V0L3E0S12=20S0=0S7=60
Psion Gold Card PCMCIA
(Advised by customer - not confirmed)
B0X2V0L3E0S12=20S0=0S7=60S37=011110
Trio Trio Fax/Data Modem Model FB1428VQE-T (V.34) B0X3V0L3E0S12=20S0=0S7=60
US Robotics Sportster Vi 14.4 Faxmodem with Voice Mail B0X2V0L3E0S12=20S0=0S7=60
US Robotics 5630B Fax Modem 56K V92 B0X2V0L3E0S12=20S0=0S7=60
X
US Robotics 5668B message Modem 56K V92 B0X2V0L3E0S12=20S0=0S7=60
Zoom 56K Dual Mode Modem – External (2956L or 3094L) B0X2V0L3E0S12=20S0=0S7=60S37=5
Zoom 3090 Mini USB 56K B0X2V0L3E0S12=20S0=0S7=60
X
Zoom 56K 3049C X2V0L3E0S12=20S0=0S7=60+MS=V22 *V6.8/3.8 are required
X
The Galaxy Gold and Event Monitoring default Modem Reset String is: B0X2V0L3E0S12=20S0=0S7=60
(Adding S37=5 helps with some modems)
* For modems with the Conexant Chipset, at least V6.8 Galaxy Gold and V3.8 Event Monitoring are required. Earlier versions of Galaxy Gold and Event Monitoring will not work with
these modems.
Page 71

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy and is the answer not in the manual?

Honeywell Galaxy Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy
CategorySecurity System
LanguageEnglish

Related product manuals