42 Mounting and Connection Instructions IK3 Evaluation Unit BUS-2
2.4 Electronic Fittings/Cylinders as switching devices
2.4.1 Functions
2.4.2 System design
1. Access control functionality
Data carrier with access control rights required
2. Intrusion panel set/unset
Data carrier with set/unset rights required
For details please see Mounting and Operating Manual Trafficpoint RS-485 (P32815-45-002-xx).
Operation of radio components (electronic door fittings/cylinders, typ XS Pro) as switching devices
in combination with intrusion panels. For bidirectional remote control, Trafficpoint RS-485 is
working as interface between XS Pro components and IK3 EU BUS-2.
At one Trafficpoint (randomly mixed) can be operated simultaneously.up to 8 XS Pro components
Occupied switching devices:
Each IK3 EU occupies switching devices plus the number of operated XS Pro components (The
Trafficpoint itself is not rated as a switching device).
Depending on the required number of doors within your system/projekt, the system could be
expanded by using additional IK3 EUs (alternatively Control Door Module for MB is usable).
Maximum number of possible doors, depends on number of switching devices which will be
supported by the used intrusion panel.
one
2.4.3 System extension
WINFEM
Advanced
F I
2
3
6
5
4
7
89
3
0
r
1
Alarmzentrale
561-MB100
Z
A509
024X
VdS
- Zulassungs-Nr.
Betrieb SAlarm SStörung
Info 4
Info 3
Info 2
Info 1
Pol.-Notruf
Überfall
Sabotage
Einbruch
System-
Störung
0
123
ME
GF
BA
456
789
Ü
B
E
R
F
A
L
L
F
U
N
K
T
I
O
N
S
O
N
D
E
R
F
U
N
K
T
I
O
N
Bereiche
wählen/
ansehen
Meldungen
ansehen
Zusatz-
funktionen
Gruppen
ansehen/
sperren
Melder
ansehen/
sperren
Eingabe
Quittierung
Bedienende
ALARMSTOP
unscharf
löschen
Intern
scharf-
schalten
AUS EIN
nein
ja
up to 4 readers
(types see Chapter 4.)
Conditions:
- ICP: from V12.xx
- IK3 EU BUS-2: from V11.xx
- WINFEM Advanced: from V12.xx
Trafficpoint RS-485
(max. 8 per IK3 EU)
RS-485
BUS-2
PC with
WINFEM Advanced
up to 10 m
max. 8 per module
IK3 EU
Control panel
MB24 / MB48 / MB100.10
MB-Secure in prep.
RS-485
Door
strike
Enhanced system
(see below)
Total numbers of doors: 9 per IK3 EU BUS-2
(1x Door strike + 8x XS Pro via radio)
BUS-2
XS Pro fitting
XS Pro cylinder

Table of Contents

Other manuals for Honeywell IDENT KEY 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell IDENT KEY 3 and is the answer not in the manual?

Honeywell IDENT KEY 3 Specifications

General IconGeneral
BrandHoneywell
ModelIDENT KEY 3
CategoryControl Unit
LanguageEnglish

Related product manuals