Sensepoint XCD Technical Manual SPXCDHMANEN Issue 15
27
For details of how to change the configuration of the Sensepoint XCD refer to chapter 12.
Gas Name
Default Range
Lower Alarm
Lower Alarm
Type
Higher Alarm
Higher Alarm
Type
Oxygen
25.0 % v/v
19.5 % v/v
Falling
23.5 % v/v
Rising
Hydrogen Sulfide
50.0 ppm
10.0 ppm
Rising
20.0 ppm
Rising
Carbon Monoxide
300 ppm
100 ppm
Rising
200 ppm
Rising
Hydrogen
1,000 ppm
200 ppm
Rising
400 ppm
Rising
Nitrogen Dioxide
10.0 ppm
5.0 ppm
Rising
10.0 ppm
Rising
Flammable IR
100 % LEL
20 % LEL
Rising
40 % LEL
Rising
Flammable CAT
100 % LEL
20 % LEL
Rising
40 % LEL
Rising
Carbon Dioxide IR
2.00 % v/v
0.40 % v/v
Rising
0.80 % v/v
Rising