EasyManua.ls Logo

Honeywell Sensepoint XCD - Replacing Transmitter Modules

Honeywell Sensepoint XCD
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sensepoint XCD Technical Manual SPXCDHMANEN Issue 15
44
Replacing Modules within the Transmitter
Two replaceable module assemblies are located within the transmitter housing. The Display Module and
the Terminal Module.
The Display Module is simply removed by unplugging it from the Terminal Module (this procedure is
done during normal installation).
To replace the Terminal Module, use the following procedure:
1. Unscrew and remove the Transmitter Cover
2. Lift the handle and un-plug and remove the Display Module.
3. Unplug the connection terminals and lift them clear of
the Terminal Module.
4. Unplug the connector for the sensor.
5. Loosen and remove the three cross-headed screws
that secure the Terminal Module to the Transmitter housing.
6. Carefully lift the Terminal Module from the transmitter housing.
7. Fit the new Terminal Module using the above procedure
in reverse order.