EasyManuals Logo

Honeywell Sensepoint XCD User Manual

Honeywell Sensepoint XCD
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
Sensepoint XCD Technical Manual SPXCDHMANEN Issue 15
61
14. Ordering information
Part number
Description
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, LM25 and M20 Entry)
SPXCDALMFX
ATEX/IECEx/AP* Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry
SPXCDALMRX
ATEX/IECEx/AP* Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry
SPXCDALMPX
ATEX/IECEx/AP* Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry
SPXCDALMO1
ATEX/IECEx/AP* Oxygen 25.0% v/v with LM25, M20 Entry
SPXCDALMHX
ATEX/IECEx/AP* Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry
SPXCDALMCX
ATEX/IECEx/AP* Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry
SPXCDALMG1
ATEX/IECEx/AP* Hydrogen 0-1000ppm with LM25, M20 Entry
SPXCDALNNX
ATEX/IECEx/AP* Nitrogen Dioxide 0-50ppm with Aluminum alloy, M20 Entry
SPXCDALMB1
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with LM25, M20 Entry
SPXCDALMB2
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with LM25, M20 Entry
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, 316SS and M20 Entry)
SPXCDASMFX
ATEX/IECEx/AP* approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
SPXCDASMRX
ATEX/IECEx/AP* approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
SPXCDASMPX
ATEX/IECEx/AP* approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
SPXCDASMO1
ATEX/IECEx/AP* approved Oxygen 25.0% v/v with 316SS, M20 Entry
SPXCDASMHX
ATEX/IECEx/AP* approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry
SPXCDASMCX
ATEX/IECEx/AP* approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry
SPXCDASMG1
ATEX/IECEx/AP* approved Hydrogen 0-1000ppm with 316SS, M20 Entry
SPXCDASNNX
ATEX/IECEX/ AP* approved Nitrogen Dioxide 0-50ppm with SS316, M20 Entry
SPXCDASMB1
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with 316SS, M20 Entry
SPXCDASMB2
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with 316SS, M20 Entry
Sensepoint XCD transmitter and sensor KIT (UL, LM25 and 3/4' NPT Entry)
SPXCDULNFX
UL/cUL approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4’ NPT Entry
SPXCDULNRX
UL/cUL approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4’ NPT Entry
SPXCDULNPX
UL/cUL approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4’ NPT Entry
SPXCDULNO1
UL/cUL approved Oxygen 25.0% v/v with LM25, 3/4’ NPT Entry
SPXCDULNHX
UL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4’ NPT Entry
SPXCDULNCX
UL/cUL approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4’ NPT Entry
SPXCDULNG1
UL/cUL approved Hydrogen 0-1000ppm with LM25, 3/4’ NPT Entry
SPXCDULNNX
UL approved SP XCD Nitrogen Dioxide 0-50ppm with LM25, 3/4’ NPT Entry
SPXCDULNB1
UL/cUL approved Carbon Dioxide IR 0-2.00% v/v with LM25, 3/4’ NPT Entry
SPXCDULNB2
UL/cUL approved Carbon Dioxide IR 0-5.00% v/v with LM25, 3/4’ NPT Entry
Sensepoint XCD transmitter and sensor KIT (UL, 316SS and 3/4’ NPT Entry)
SPXCDUSNFX
UL/cUL approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4’ NPT Entry
SPXCDUSNRX
UL/cUL approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4’ NPT Entry
SPXCDUSNPX
UL/cUL approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4’ NPT Entry
SPXCDUSNO1
UL/cUL approved Oxygen 25.0% v/v with 316SS, 3/4’ NPT Entry
SPXCDUSNHX
UL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4’ NPT Entry
SPXCDUSNCX
UL/cUL approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4’ NPT Entry
SPXCDUSNG1
UL/cUL approved Hydrogen 0-1000ppm with 316SS, 3/4’ NPT Entry
SPXCDUSNNX
UL approved SP XCD Nitrogen Dioxide 0-50ppm with SS316, 3/4’ NPT Entry
SPXCDUSNB1
UL/cUL approved Carbon Dioxide IR 0-2.00% v/v with 316SS, 3/4’ NPT Entry
SPXCDUSNB2
UL/cUL approved Carbon Dioxide IR 0-5.00% v/v with 316SS, 3/4’ NPT Entry
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, LM25 and M20 Entry with Modbus)
SPXCDALMFXM
ATEX/IECEx/AP* Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with Modbus
SPXCDALMRXM
ATEX/IECEx/AP* Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with Modbus
SPXCDALMPXM
ATEX/IECEx/AP* Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with Modbus
SPXCDALMO1M
ATEX/IECEx/AP* Oxygen 25.0% v/v with LM25, M20 Entry, with Modbus
SPXCDALMHXM
ATEX/IECEx/AP* Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry, with Modbus
SPXCDALMCXM
ATEX/IECEx/AP* Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry, with Modbus
SPXCDALMG1M
ATEX/IECEx/AP* Hydrogen 0-1000ppm with LM25, M20 Entry, with Modbus
SPXCDALNNXM
ATEX/IECEX /AP approved Nitrogen Dioxide 0-50ppm with LM25, M20 Entry, With Modbus
SPXCDALMB1M
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with LM25, M20 Entry, with Modbus
SPXCDALMB2M
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with LM25, M20 Entry, with Modbus
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, 316SS and M20 Entry with Modbus)
SPXCDASMFXM
ATEX/IECEx/AP* approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with Modbus
SPXCDASMRXM
ATEX/IECEx/AP* approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with Modbus
SPXCDASMPXM
ATEX/IECEx/AP* approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with Modbus
SPXCDASMO1M
ATEX/IECEx/AP* approved Oxygen 25.0% v/v with 316SS, M20 Entry, with Modbus
SPXCDASMHXM
ATEX/IECEx/AP* approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry, with Modbus
SPXCDASMCXM
ATEX/IECEx/AP* approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry, with Modbus
SPXCDASMG1M
ATEX/IECEx/AP* approved Hydrogen 0-1000ppm with 316SS, M20 Entry, with Modbus
SPXCDASNNXM
ATEX/IECEX /AP approved Nitrogen Dioxide 0-50ppm with SS316, M20 Entry, With Modbus
SPXCDASMB1M
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with 316SS, M20 Entry, with Modbus
SPXCDASMB2M
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with 316SS, M20 Entry, with Modbus
UL APPROVAL (Epoxy Coated Aluminum Alloy, LM25, With Modbus)
SPXCDULNFXM
UL/cUL approved Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4’ NPT Entry, with Modbus
SPXCDULNRXM
UL/cUL approved Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4’ NPT Entry, with Modbus
SPXCDULNPXM
UL/cUL approved Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4’ NPT Entry, with Modbus
SPXCDULNO1M
UL/cUL approved Oxygen 25.0% v/v with LM25, 3/4’ NPT Entry, with Modbus
SPXCDULNHXM
UL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4’ NPT Entry, with Modbus

Other manuals for Honeywell Sensepoint XCD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Sensepoint XCD and is the answer not in the manual?

Honeywell Sensepoint XCD Specifications

General IconGeneral
TypeFixed Gas Detector
Ingress ProtectionIP66/67
DisplayLCD
Output4-20 mA, Relay
CertificationATEX, IECEx
Sensor TypeElectrochemical, Infrared
Humidity0 to 99% RH (non-condensing)
MaterialStainless Steel
Detection PrincipleDepends on Sensor Type
Power Supply24 VDC nominal (17-32 VDC)