Sensepoint XCD Technical Manual SPXCDHMANEN Issue 15
61
14. Ordering information
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, LM25 and M20 Entry)
ATEX/IECEx/AP* Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry
ATEX/IECEx/AP* Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry
ATEX/IECEx/AP* Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry
ATEX/IECEx/AP* Oxygen 25.0% v/v with LM25, M20 Entry
ATEX/IECEx/AP* Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry
ATEX/IECEx/AP* Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry
ATEX/IECEx/AP* Hydrogen 0-1000ppm with LM25, M20 Entry
ATEX/IECEx/AP* Nitrogen Dioxide 0-50ppm with Aluminum alloy, M20 Entry
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with LM25, M20 Entry
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with LM25, M20 Entry
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, 316SS and M20 Entry)
ATEX/IECEx/AP* approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
ATEX/IECEx/AP* approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
ATEX/IECEx/AP* approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
ATEX/IECEx/AP* approved Oxygen 25.0% v/v with 316SS, M20 Entry
ATEX/IECEx/AP* approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry
ATEX/IECEx/AP* approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry
ATEX/IECEx/AP* approved Hydrogen 0-1000ppm with 316SS, M20 Entry
ATEX/IECEX/ AP* approved Nitrogen Dioxide 0-50ppm with SS316, M20 Entry
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with 316SS, M20 Entry
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with 316SS, M20 Entry
Sensepoint XCD transmitter and sensor KIT (UL, LM25 and 3/4' NPT Entry)
UL/cUL approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4’ NPT Entry
UL/cUL approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4’ NPT Entry
UL/cUL approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4’ NPT Entry
UL/cUL approved Oxygen 25.0% v/v with LM25, 3/4’ NPT Entry
UL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4’ NPT Entry
UL/cUL approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4’ NPT Entry
UL/cUL approved Hydrogen 0-1000ppm with LM25, 3/4’ NPT Entry
UL approved SP XCD Nitrogen Dioxide 0-50ppm with LM25, 3/4’ NPT Entry
UL/cUL approved Carbon Dioxide IR 0-2.00% v/v with LM25, 3/4’ NPT Entry
UL/cUL approved Carbon Dioxide IR 0-5.00% v/v with LM25, 3/4’ NPT Entry
Sensepoint XCD transmitter and sensor KIT (UL, 316SS and 3/4’ NPT Entry)
UL/cUL approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4’ NPT Entry
UL/cUL approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4’ NPT Entry
UL/cUL approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4’ NPT Entry
UL/cUL approved Oxygen 25.0% v/v with 316SS, 3/4’ NPT Entry
UL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4’ NPT Entry
UL/cUL approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4’ NPT Entry
UL/cUL approved Hydrogen 0-1000ppm with 316SS, 3/4’ NPT Entry
UL approved SP XCD Nitrogen Dioxide 0-50ppm with SS316, 3/4’ NPT Entry
UL/cUL approved Carbon Dioxide IR 0-2.00% v/v with 316SS, 3/4’ NPT Entry
UL/cUL approved Carbon Dioxide IR 0-5.00% v/v with 316SS, 3/4’ NPT Entry
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, LM25 and M20 Entry with Modbus)
ATEX/IECEx/AP* Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with Modbus
ATEX/IECEx/AP* Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with Modbus
ATEX/IECEx/AP* Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, M20 Entry, with Modbus
ATEX/IECEx/AP* Oxygen 25.0% v/v with LM25, M20 Entry, with Modbus
ATEX/IECEx/AP* Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry, with Modbus
ATEX/IECEx/AP* Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry, with Modbus
ATEX/IECEx/AP* Hydrogen 0-1000ppm with LM25, M20 Entry, with Modbus
ATEX/IECEX /AP approved Nitrogen Dioxide 0-50ppm with LM25, M20 Entry, With Modbus
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with LM25, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with LM25, M20 Entry, with Modbus
Sensepoint XCD transmitter and sensor KIT (ATEX/IECEx/AP*, 316SS and M20 Entry with Modbus)
ATEX/IECEx/AP* approved Methane CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Oxygen 25.0% v/v with 316SS, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Hydrogen 0-1000ppm with 316SS, M20 Entry, with Modbus
ATEX/IECEX /AP approved Nitrogen Dioxide 0-50ppm with SS316, M20 Entry, With Modbus
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-2.00% v/v with 316SS, M20 Entry, with Modbus
ATEX/IECEx/AP* approved Carbon Dioxide IR 0-5.00% v/v with 316SS, M20 Entry, with Modbus
UL APPROVAL (Epoxy Coated Aluminum Alloy, LM25, With Modbus)
UL/cUL approved Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4’ NPT Entry, with Modbus
UL/cUL approved Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4’ NPT Entry, with Modbus
UL/cUL approved Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4’ NPT Entry, with Modbus
UL/cUL approved Oxygen 25.0% v/v with LM25, 3/4’ NPT Entry, with Modbus
UL/cUL approved Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4’ NPT Entry, with Modbus