20
VISTA-128BPT/128BPT-SIA/250BPT PROGRAMMING GUIDE
FIELD TITLE and DATA ENTRIES Default Values
23
Multiple Alarms (partition-specific)
0 = disable
[1] A E
Enabled: Allows more than one alarm sounding for a given zone during an armed period.
Disabled: The bell output will only activate once per zone per armed period for any audible zone type. Multiple alarm
soundings will not occur more than the duration programmed in ∗13.
After the duration expires, the sounder will
activate again for the same duration; will continue until the control is disarmed. This has no impact on the
number of communication messages transmitted.
UL
MUST BE 1 FOR UL INSTALLATIONS.
24
Ignore Expansion Zone Tamper
0 = disable (tamper detection)
1 = enable (no tamper detection)
[1] AAA E
If disabled, the system monitors the tampers on expansion zones.
NOTE: Only applicable to certain polling loop sensors with tamper switches or 5800 Series
transmitters and does not apply
to ECP Device Tamper 8XX zones.
UL
MUST BE 0 FOR UL INSTALLATIONS.
26
INTELLIGENT TEST REPORT
0 = disable
[0] AAA E
Enabled: No test report is sent if any other type of report was sent since the last test report.
Disabled: Test reports are sent at the set intervals, regardless of whether or not any other report has been sent.
MUST BE 0 FOR UL INSTALLATIONS.
27
Test Report Interval
Enter 0001-9999 for the test report interval in hours.
Enter 0000 for test reporting.
[0024] AAA E E E E
If a test report is desired, enter a test code in Report Code Programming in #93 Menu Mode and set first test report time in
field ∗83.
UL
MAXIMUM TEST REPORT INTERVAL IS 0024 FOR UL INSTALLATIONS.
28
Power-Up in Previous State
0 = disable
[1] AAA E
Enabled: The system, upon power-up, reverts to its status prior to a complete power loss.
Disabled: The system always powers up in a disarmed state.
NOTE: Neither authority level 0 nor 5 can be used to disarm the system if the control powers up armed.
UL
UST BE SET TO 0 FOR UL INSTALLATIONS.
29
Quick Arm (partition-specific)
0 = disable
[1] AAA E
Enabled:
Allows arming of the burglary system in AWAY, STAY, INSTANT, or MAXIMUM mode by using the [#] key instead of
the user code.
NOTES:
• When armed, the system reports closing as User 0 if Open/Close reporting for User #2 (typically a Master level user)
was enabled for a given partition.
• If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot disarm the system.
30
Phone Linecut Detect
0 = disable
[1] AAA E
Enabled: Indicates PHONE LINE CUT on the keypad when phone line voltage drops below 2VDC for approximately 120
seconds.
NOTES:
• The panel will send/log Contact ID code E351 Telco Fault over an AlarmNet ECP Communicator. (T
to be enabled in #93 Report Code, Programming, System Group 2 under TELCO TROUBLE.)
• R351 Telco Fault is sent/logged when phone line voltage has returned for approximately 60 seconds.