VISTA-128BPT/128BPT-SIA/250BPT PROGRAMMING GUIDE
FIELD TITLE and DATA ENTRIES Default Values
23
Multiple Alarms (partition-specific)
0 = disable
1 = enable
[1] A E
Enabled: Allows more than one alarm sounding for a given zone during an armed period.
Disabled: The bell output will only activate once per zone per armed period for any audible zone type. Multiple alarm
soundings will not occur more than the duration programmed in 13.
After the duration expires, the sounder will
activate again for the same duration; will continue until the control is disarmed. This has no impact on the
number of communication messages transmitted.
UL
MUST BE 1 FOR UL INSTALLATIONS.
24
Ignore Expansion Zone Tamper
0 = disable (tamper detection)
1 = enable (no tamper detection)
[1] AAA E
If disabled, the system monitors the tampers on expansion zones.
NOTE: Only applicable to certain polling loop sensors with tamper switches or 5800 Series
transmitters and does not apply
to ECP Device Tamper 8XX zones.
UL
MUST BE 0 FOR UL INSTALLATIONS.
26
INTELLIGENT TEST REPORT
0 = disable
1 = enable
[0] AAA E
Enabled: No test report is sent if any other type of report was sent since the last test report.
Disabled: Test reports are sent at the set intervals, regardless of whether or not any other report has been sent.
UL
MUST BE 0 FOR UL INSTALLATIONS.
27
Test Report Interval
Enter 0001-9999 for the test report interval in hours.
Enter 0000 for test reporting.
[0024] AAA E E E E
If a test report is desired, enter a test code in Report Code Programming in #93 Menu Mode and set first test report time in
field 83.
UL
MAXIMUM TEST REPORT INTERVAL IS 0024 FOR UL INSTALLATIONS.
28
Power-Up in Previous State
0 = disable
1 = enable
[1] AAA E
Enabled: The system, upon power-up, reverts to its status prior to a complete power loss.
Disabled: The system always powers up in a disarmed state.
NOTE: Neither authority level 0 nor 5 can be used to disarm the system if the control powers up armed.
UL
UST BE SET TO 0 FOR UL INSTALLATIONS.
29
Quick Arm (partition-specific)
0 = disable
1 = enable
[1] AAA E
Enabled:
Allows arming of the burglary system in AWAY, STAY, INSTANT, or MAXIMUM mode by using the [#] key instead of
the user code.
NOTES:
When armed, the system reports closing as User 0 if Open/Close reporting for User #2 (typically a Master level user)
was enabled for a given partition.
If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot disarm the system.
30
Phone Linecut Detect
0 = disable
1 = enable
[1] AAA E
Enabled: Indicates PHONE LINE CUT on the keypad when phone line voltage drops below 2VDC for approximately 120
seconds.
NOTES:
The panel will send/log Contact ID code E351 Telco Fault over an AlarmNet ECP Communicator. (T
he E351 report needs
to be enabled in #93 Report Code, Programming, System Group 2 under TELCO TROUBLE.)
R351 Telco Fault is sent/logged when phone line voltage has returned for approximately 60 seconds.