25
SECTION 3: DATA FIELD DESCRIPTIONS
FIELD TITLE and DATA ENTRIES Default Values
90
Secondary Subscriber Account Number (partition-
specific)
Enter 00-09; B-F (11-15)
[Blank] A | E A A | E A A | E A A | E AA | E A A | E A A | E A
A | E
Enter a 4- or 10-digit (depending on report format in 47) secondary
subscriber account number. Each number requires a
2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 4-digit account number is to be used, enter data only in
the first four locations, and enter in the fifth location. Example: 4-digit account # 1234 would be 01 02 03 04 .
NOTE: This field must be programmed if a secondary phone number is used (field 34). This account number can be the
same as the primary account number.
1
07
Check or TRBL Display
0 = CHECK
1 = TRBL
[0] A E
Select whether the system should display TRBL or CHECK for trouble conditions.
1
11
Zone Bypass After Disarm
0 = disable
1 = enable
[00000000] A
E
1
E
AA
E
2
E
AA
E
3
E
AA
E
4
E
AA
E
5
E
AA
E
6
E
AA
E
7
E
AA
E
8
E
Disabled: The USER CODE + OFF will not unbypass zones.
Enabled: The USER CODE + OFF will unbypass zones.
Unbypassing Process:
To unbypass ALL zones, enter USER CODE + # + 64.
To unbypass zones INDIVIDUALLY, you must enter USER CODE + 6 + zone number.
NOTES:
Automatically bypassed zones unbypass upon disarming of the control (e.g., STAY mode, Auto-STAY, etc.).
Vent zones and zones bypassed by a programmed Auto-Bypass schedule (Timed Driven Event) are considered
“manual bypasses” and will not be unbypassed upon disarming the system.
Zones that were in a bypassed state at the time a System Shutdown is sent from the Compass Downloading
software will be unbypassed when the System Shutdown is removed.
1
15
Cancel Verify
0 = disable
1 = enable alarm output pulse upon kissoff of Cancel report.
[1] A E
Enabled: The bell output will pulse the alarm output 3 times and displays "Cancel report sent to central station" when the
panel receives a kissoff from central station for the cancel report.
NOTE: 1
52 must be enabled to send a Cancel report to the central station.
NOTE: This feature is enabled by default, as is the cancel report code, for SIA compliance.
1
17
Lobby Partition
0 = none
1-8 = partition number
[0] A E
Select the Common Lobby Partition.
NOTE: The Lobby partition must be the highest partition enabled in the panel, for instance if you have 3 partitions
enabled, partition 3 should be your common lobby partition.
1
18
Affects Lobby (partition-specific)
0 = disable
1 = enable
[0] A E
If enabled, causes lobby partition to disarm when this partition disarms.
NOTE: This partition must be armed before lobby can be armed.
1
19
Arms Lobby (partition-specific)
0 = disable
1 = enable
[0] A E
If enabled, arming this partition causes the system to attempt to arm the lobby partition automatically. To enable this field
,
field 118 must also be enabled (partition-specific).
NOTES:
The lobby cannot be armed unless all partitions programmed for “affect” (field 118) is already armed.
If his field is enabled, Field 118 for this partition must also be enabled.