VISTA-128BPT/128BPT-SIA/250BPT PROGRAMMING GUIDE
FIELD TITLE and DATA ENTRIES Default Values
1
20
Exit Error Logic Enable
0 = disable
1 = enable
[1] A E
Exit Error Logic functions as follows:
At the end of the exit delay, if a door is left open or an interior zone is faulted, starts the entry delay period, and sounds the
bell(s), siren(s), and keypad sounders for the duration of entry delay. This gives the user time to re-enter the premises and
disarm the system before exit error report occurs.
Process:
1. If the user does not re-enter the premises and disarm the system, the system bypasses the faulted entry/exit and/or
interior zone(s).
2. The rest of the system is armed.
3. The following dialer reports are sent to the central station if programmed:
Exit Error by Zone
Entry/Exit or Interior Alarm with the zone number
Bypass reports
NOTE: This field has been eliminated in the Vista-128SIA software.
UL
EXIT ERROR LOGIC IS NOT SUITABLE FOR USE IN A UL INSTALLATION.
1
21
Exit Delay Reset
0 = disable
1 = enable
[1] A E
If enabled, when the panel is armed, the normal exit delay begins. After the user exits, closes the door and then re-enters
the premises, the exit delay time is reset to the programmed value.
NOTES:
Exit Delay Reset is designed to allow an operator to re-enter the premises to retrieve a forgotten item without
triggering an alarm.
This feature may only be activated once after arming.
UL
EXIT DELAY RESET IS NOT SUITABLE FOR USE IN A UL INSTALLATION.