27 = Access Point Allows more than one relay to be controlled by activation if access point request.
29 = Momentary Exit This Zone Type is used with VISTA-KEY access control ONLY.
31 = End of Exit Time A relay programed to stop/start on 31 will stop/start on the first Exit time to end
(should be Entry/Exit #1). NOTE: If programmed to pulse on A Zone Type 31
it will pulse at the end of E/E#1 and E/E#2.
32 = Start of Entry
Time
Start of Entry time #1 or #2 activate the
output.
33 = Any Burglary
Alarm
Encompasses alarms on Zone Types:
01 = Entry/Exit #1, Burglary
02 = Entry/Exit #2, Burglary
03 = Perimeter, Burglary
04 = Interior Follower, Burglary
05 = Trouble Day/Alarm Night
07 = 24 Hr. Audible Alarm
10 = Interior Delay, Burglary
34 = Code + [#] + 71
Key Entry
Any user authority level has access to this command.
35 = Code + [#] + 72
Key Entry
Any user authority level has access to this command.
36 = At Bell Timeout
(13)
Occurs when the Time Out expires or disarming, which ever happens first.
37 = 2 Times Bell
Timeout
Occurs after two times the Bell Time Out expires or disarming, which ever happens
first.
38 = Chime Follows the chime feature for the
compatible Zone Types, the chime
mode must be enabled.
39 = Fire Alarm System Event '39 Any Fire'
encompasses alarms on zone types:
09 = Fire Without Verification
16 = Fire With Verification
40 = Bypassing Occurs when a zone is bypassed Stops when a bypass is cleared.
41 = AC Power Fail
Follows the dialer for AC loss, if AC
loss reporting is randomized (19),
the
Output will follow this randomized
time.
Follows AC Restore.
If you set the panel for Normal AC loss reporting, the panel should dial within
about 2 minutes of AC loss and the Output will throw at the same time.
42 = System Battery
Low
Follows a panel low battery. Follows the Low Battery Restore.
43 = Communication
failure
Follows a telephone communication
failure.
Stop when the “Comm. Failure” has
cleared.
44 = RF Low Battery
Follows low battery on a 5800 wireless
transmitter.
Stop when the low battery restores.
45 = Polling Loop
Failure
Follows Zone 997 (polling loop short)
regardless if zone 997 has a zone type
programmed.
Follows removal of short on polling
loop.
47 = Console Failure
Supervision zones for ECP supervision of zone 8XX, where XX = the device address.
51 = RF Receiver
Failure
Supervision zones for ECP supervision of zone 8XX, where XX = the device address.
52 = Kissoff
Occurs when a Kissoff from Central Station is received.
54 = Fire Zone Reset
STARTS a relay when a FIRE reset
command is entered.
STOP program is usually Zone Type 57.
55 = Disarm + 1
Minute
Starts one minute after disarm.
56 = XX Minutes
Not a feature. Requires and entry in programming
location 174 (XX Minutes)
57 = YY Seconds
Note a feature. Requires and entry in programming
location 175 (YY seconds).