EasyManuals Logo

HP 16-port SCS User Manual

HP 16-port SCS
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
SCS commands 60
Server CLI
The Server CLI command:
Specifies the console port type
Specifies the CLI access character
Enables or disables device connection from the console port
Specifies a modem initialization string
Specifies port history mode operations
Specifies a port time-out value
At least one parameter must be specified.
Access right: SCON
Access level: APPLIANCEADMIN
Syntax:
server cli [type=<type>] [char=^<char>] [connect=on|off]
[history=hold|auto,clear|keep] [modeminit=“<string>”] [timeout=<time-out>]
Table 5-14 Server CLI command parameters
Parameter Description
TYPE=<type> Terminal type to be used on the console port. The entire name of the type must be specified.
Abbreviations are not permitted. Valid types are: ASCII, VT52, VT100, VT102, VT220, and
VT320.
Default: ASCII
CHAR=^<char> CLI access character in the range A through _ (underscore). (The allowable ASCII range is
0x41-0x5F and 0x61-0x7A.) The CLI access character, when pressed simultaneously with the
Ctrl key during a session with an attached serial device, will suspend the session with the
device and place you in CLI command mode. This value will be used if the Port Set
command of a port contains a Char=None parameter.
Default = ^d
CONNECT=ON|OFF Enables or disables the ability to use the Connect command from the console port. When
enabled, a console port user can use the Connect command to establish a connection to the
serial device attached to another SCS serial port. When disabled, you cannot use the
Connect command from the console port.
Default = ON
HISTORY=HOLD|AUTO,CLE
AR|KEEP
Port history file processing options during connection (Hold or Auto) and when a session ends
(Clear or Keep):
Hold—Upon connection, you are informed of how much data is in the history buffer, but the
data is not displayed.
Auto—Upon connection, you are informed of how much data is in the history buffer, and it is
then displayed.
Clear—The history buffer content is cleared when a session ends.
Keep—The history buffer content is retained when a session ends.
You cannot specify both Clear and Keep or both Hold and Auto.
Default = HOLD,CLEAR
MODEMINIT=“<string>” Modem initialization string, enclosed in quotation marks. Must contain at least ATV1 and
S0=1.
Default = “” (no modem is attached to the console port)