Loading...
Long wavelengthShort wavelengthCable size
nl
(microns)
Port speed
N/A300 m (984 ft)62.5
4 km (2.48 miles)N/A9
FCoE Converged Network Switch data flow latency
Table 30 describes the data flow latency for the FCoE Converged Network Switch.
Table 30 Data flow latency for the FCoE Converged Network Switch
Size in nanosecondsData flow latency type
+/ 700 nsFC port to FC port
570 nsCEE port to CEE port (same ASIC)
1,050 nsCEE port to CEE port (different ASIC)
1,670 nsFCoE to FC
Fibre Channel port specifications
The Fibre Channel ports in the 8-Gb SAN Switch are compatible with SWL, LWL, and ELWL SFP
transceivers. The strength of the signal is determined by the type of transceiver in use.
The ports meet all required safety standards.
The ports are capable of operating at 1, 2, 4, or 8 Gb/s and are able to autonegotiate to the maximum
link speed.
POST and boot specifications
The switch performs POST by default each time it is powered on or rebooted or the system is reset.
Boot time with POST is usually about 1 to 3 minutes.
POST can be skipped after subsequent reboots by entering the fastboot command. For more
information about this command, see the Fabric OS Command Reference Manual.
POST
The success/fail results of the diagnostic tests that run during POST can be monitored through LED
activity, the error log, or the CLI.
POST performs the following tasks:
Conducts preliminary POST diagnostics
Initializes the operating system
Initializes the hardware
Runs diagnostic tests on several functions, including circuitry, port functionality, memory, statistics
counters, and serialization
8-Gb SAN Switch Hardware Reference Guide 93