Nonport side of the 1606 Extension SAN Switch
Figure 11 shows the nonport side of the 1606 Extension SAN Switch, which contains the combined
power supplies and fans.
7. Fan assembly 11. Fan and power supply assembly #2
8. FRU LED2. Fan and power supply assembly #1
9. Power supply #13. Fan assembly #2
10. Fan assembly #14. FRU LED
11. FRU handle5. Power supply #2
12. FRU handle6. Fan assembly #2
Figure 11 Nonport side of the 1606 Extension SAN Switch
.
Installing and activating Port Upgrade licenses
1. Use the portshow command to verify the number of ports licensed on your switch. The port
status output indicates Started and Licensed for enabled ports. For more information on this
command, see the Fabric OS Command Reference Manual.
2. Obtain the WWN from the Switch ID pull-out tab located on the port side of your switch.
Alternately, you can use the switchshow command to display the WWN.
3. Contact your HP representative to purchase the appropriate Port Upgrade license. HP requires
the switch WWN obtained in Step 2 to assign a license key.
8-Gb SAN Switch Hardware Reference Guide 25