EasyManua.ls Logo

HP 1606 - Data Transmission Ranges; Laser Data Transmission Ranges for the 8;8 and 8;24 SAN Switches; Laser Data Transmission Ranges for the 8;40 SAN Switch

HP 1606
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Data transmission ranges
See Table 24 through Table 29 for 8-Gb SAN Switch data transmission ranges for the different cable
types and port speeds.
Table 24 Laser data transmission ranges for the 8/8 and 8/24 SAN Switches
Long wavelengthShort wavelengthCable size
nl
(microns)
Port speed
N/A500 m (1,640 ft)501 Gb/s
N/A300 m (984 ft)62.5
Up to 10 km (6.2 miles) optional
long wave SFPs required
N/A9
N/A300 m (984 ft)502 Gb/s
N/A150 m (492 ft)62.5
N/AN/A9
N/A150 m (492 ft)504 Gb/s
N/A70 m (230 ft)62.9
N/AN/A9
N/A150 m508 Gb/s
N/A21 m62.5
10 kmN/A9
Table 25 Laser data transmission ranges for the 8/40 SAN Switch
Extended long
wavelength
Long wavelengthShort wavelengthCable size
nl
(microns)
Port speed
N/A10 km (6.2 miles)500 m (1,640 ft)501 Gb/s
N/A10 km (6.2 miles)300 m (984 ft)62.5
40 km (24.8 miles)10 km (6.2 miles)N/A9
N/A10 km (6.2 miles)300 m (984 ft)502 Gb/s
N/A10 km (6.2 miles)150 m (492 ft)62.5
40 km (24.8 miles)10 km (6.2 miles)
without an HP Extended
Fabrics license
50 to 100 km with an
HP Extended Fabrics
license
N/A9
N/AN/A150 m (492 ft)504 Gb/s
8-Gb SAN Switch Hardware Reference Guide 89