EasyManua.ls Logo

HP 5334B - 4-21. T.I. A+B

HP 5334B
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Observe:
The
HP
5334B front panel displays all dashes and Channel
B
trigger light stops flashing.
14.
Set:
CHAN
B
500
........................................................................................................
OFF
I
Observe:
Condition prior to switching in 50n impedance.
15. Set:
CHAN B
XI0 ATTN
...........................................................................................
ON
Observe:
The
HP
5334B front panel displays all dashes and Channel
B
trigger light stops flashing.
16.
Set:
CHAN
B
XI0 ATTN
...........................................................................................
OFF
Observe:
Condition prior to switching in XI0 A'ITN.
Test Record:
Mark Pass or Fail on the Operational Verification Test Record Card, line
5.
What
Checked:
Relays and circuitry.
For Failures:
Refer to Section VIII of this manual. The Input Amplifier and Executive Blocks are the main com-
ponents of this test. Other blocks involved are DAC, Measurement, and Front Panel blocks.
4-21.
T.I.
A+B
Description:
Slope switch verification.
Procedure:
1.
Connect the rear panel TIME BASE oscillator signal to the Channel A Input.
2.
Set the
HP
5334B as follows:
Reinitialize the 5334B.
C0M.A
................................................................................................................
ON
TRIGGER LEVEL controls
..............................................................................
set to OV
+
0.2V
using READ LEVELS
"L"
mode
AUTO TRIG
.........................................................................................................
OFF
CHAN A and B 500
............................................................................................
ON
GATE TIME
.........................................................................................................
1
Second
FUNCTION
...........................................................................................................
T.I. A+ B
Observe:
The HP 5334B front panel displays
0
ns
+-
6
ns.
3.
Set both:
Channel A and B Negative SLOPE
..................................................................
ON
(Counter now triggers on negative slope.)
Observe:
The HP 5334B front panel displays 0 ns
+-
6
ns.
HP
5334B
-
Service Manual
4-8

Table of Contents