EasyManua.ls Logo

HP 9304m - Physical Dimensions; Operating Environment; Storage Environment; Electromagnetic Emissions

HP 9304m
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and Getting Started Guide
B - 8
Physical Dimensions
Operating Environment
• Operating Temperature: 41° to 104° F, 5 ° to 40° C
• Relative Humidity: 5% – 90%, non-condensing
• Operating Altitude: 0 – 10,000 feet
Storage Environment
• Storage Temperature: -40° – 158° F, -4 0° – 70° C
• Storage Humidity: 95% maximum, non-condensing
• Storage Altitude: 10,000 feet (3,000 meter) maximum
Electromagnetic Emissions
• FCC Class A, Part 15
• EN55022/CISPR22 Class A
• VCCI Class A
Immunity
• EN55024/CISPR24
• Harmonics and Flicker IEC 61000-3-2/IEC 61000-3-3
Safety Agency Approvals
• UL 1950
• CUL/CSA-C22.2 No. 950 93
• TUV EN 60950, EN 60825
Laser
• Class 1 Laser Product
• Laser Klasse 1
• Complies with IEC 825-2:1993
Table B.3: Physical dimensions for HP devices
Platform Depth Width Length (Height) Weight
15-slot Chassis
device
15" 17.5" 29.75" 256 lbs. fully
populated
8-slot Chassis
device
15" 17.5" 23" 69.1 lbs. fully
populated
4-slot Chassis
device
15" 17.5" 9" 47.7 lbs. fully
populated

Table of Contents