158
Firmware Up
rades
3.
Usin
the
SNMP/Network Administrator
dialo
box, verify that the community
and set community names for the terminal match the community and set
community names in the SNMP mana
er.
Note
You can set the
Set Community
name for a terminal if
you have DHCP enabled by settin
DHCP Option
164
to the set community name your SNMP mana
er uses.
4.
Usin
your SNMP mana
er:
a.
Go to 1.2.3.8.1.2 (wbt3UpDnLoadTable).
b.
Go to 1.2.3.8.1.2.1.2 (wbt3UpDnLoadID), user defined strin
.
Note
The above is used in traps to identify the download
operation.
c.
Go to 1.2.3.8.1.2.1.3 (wbt3UpDnLoadOp), and set its value to
1 (Download).
d.
Go to 1.2.3.8.1.2.1.4 (wbt3UpDnLoadSrcFile), and set its value to the
absolute path of the directory where the ima
e file and params.ini are
located.
e.
Go to 1.2.3.8.1.2.1.6 (wbt3UpDnLoadFileType), and set its value to 0
(Binary).
f.
Go to 1.2.3.8.1.2.1.7 (wbt3UpDnLoadProtocol), and set its value to 0 or 1
(FTP or TFTP).
g.
Go to 1.2.3.8.1.2.1.8 (wbt3UpDnLoadFServer), and set its value to the IP
address or DNS name of the FTP or TFTP server.
h.
Go to 1.2.3.8.1.4 (wbt3SubmitLoadJob), and set its value to
1 (Ready).
Step 4h will initiate an SNMP up
rade to your terminal. If the download is
confi
ured properly, the new ima
e will download and the terminal will reboot
automatically to factory defaults.
Refer to Chapter 29, FTP Pull Firmware Up
rades, to view the dialo
boxes that
display durin
the process.