EasyManuals Logo

HP Integrity rx3600 Installation Guide

HP Integrity rx3600
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
Percentage completed: 100%
Activating firmware now, this may take several minutes.
Resetting and reinitializing controller.
Retrieving firmware version, this may take several minutes.
Current controller firmware version is 2.34.
************************************************************
Smart Array Offline Firmware Update Utility
Version: 1.04.12.00
(C) Copyright 2004 Hewlett Packard Development Company L.P.
*************************************************************
Firmware Image is not suitable for HP Smart Array
5300 Controller at Seg: 1, Bus 20, Dev: 1, Func:0
After updating the firmware, cycle the power on the system and on any external JBODS connected
to the Smart Array HBAs.
HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter: saupdate HELP
or
saupdate ?
Error Messages
The following is a list of error messages under various situations:
When keyword LIST or UPDATE is misspelled or extra parameters are specified:
Error: Syntax Error
Usage: saupdate LIST or saupdate UPDATE [ all ]
When the controller ID in the saupdate UPDATE command is not correct:
No matching controller found
When a firmware file does not exist in the saupdate UPDATE command, the example shows:
CYBORG101.BIN does not exist.
File CYBORG101.BIN: Not Found
When an invalid firmware or corrupted file is specified in the saupdate UPDATE command,
the example shows: CYBORG101.BIN does not exist.
File CYBORG101.BIN: invalid or corrupted
EBSU Utility
The EFI-based Setup Utility (EBSU) provides an easy-to-use interface for flashing firmware, partitioning
the hard disk, installing diagnostic tools, configuring storage controllers, and running other EFI
utilities.
NOTE: You can use EBSU to update firmware for many different devices in the system. A Smart
Array Controller is shown as an example.
To update the Smart Array Controller firmware:
1. Power on the server. The server boots to EFI. The EFI Boot Manager may be used from the
enhanced interface (grey background) or the legacy interface (black background).
2. Load the HP Smart Setup media into the server DVD drive.
3. From the EFI Boot Menu, select Internal Bootable DVD and press Enter. EBSU starts and displays
the Welcome screen.
66 Installing the System

Table of Contents

Other manuals for HP Integrity rx3600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx3600 and is the answer not in the manual?

HP Integrity rx3600 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx3600
CategoryServer
LanguageEnglish

Related product manuals