9-20
Time Protocols
TimeP: Viewing, Selecting, and Configuring
Figure 9-13. Example of Configuring Timep for Manual Operation
Changing the TimeP Poll Interval. This command lets you specify how
long the switch waits between time polling intervals. The default is 720
minutes and the range is 1 to 9999 minutes. (This parameter is separate from
the poll interval parameter used for SNTP operation.)
Syntax: ip timep dhcp interval < 1 . . 9999 >
ip timep manual interval < 1 . . 9999 >
For example, to change the poll interval to 60 minutes:
ProCurve(config)# ip timep interval 60
Disabling Time Synchronization Without Changing the TimeP
Configuration. The recommended method for disabling time synchroniza-
tion is to use the timesync command. This halts time synchronization without
changing your TimeP configuration.
Syntax: no timesync
For example, suppose TimeP is running as the switch’s time synchronization
protocol, with
DHCP as the TimeP mode, and the factory-default polling
interval. You would halt time synchronization with this command:
ProCurve(config)# no timesync
If you then viewed the TimeP configuration, you would see the following:
Figure 9-14. Example of TimeP with Time Sychronization Disabled

Table of Contents

Other manuals for HP ProCurve 2510-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2510-24 and is the answer not in the manual?

HP ProCurve 2510-24 Specifications

General IconGeneral
ModelHP ProCurve 2510-24
Switching Capacity8.8 Gbps
LayerLayer 2
Form FactorRack-mountable
MAC Address Table Size8000 entries
Jumbo Frame SupportYes
PowerAC 120/230 V (50/60 Hz)
ManagementWeb, SNMP, CLI
FeaturesVLAN support, QoS
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Operating Temperature0 to 40 °C
Operating Humidity15% to 95% (non-condensing)
Dimensions44.25 x 17.3 x 4.45 cm

Related product manuals