9-19
Time Protocols
TimeP: Viewing, Selecting, and Configuring
The commands and output would appear as follows:
Figure 9-12. Example of Enabling TimeP Operation in DHCP Mode
Enabling Timep in Manual Mode. Like DHCP mode, configuring TimeP
for Manual mode enables TimeP. However, for manual operation, you must
also specify the IP address of the TimeP server. (The switch allows only one
TimeP server.) To enable the TimeP protocol:
Syntax: timesync timep
Selects Timep.
ip timep manual <ip-addr>
Activates TimeP in Manual mode with a specified TimeP
server.
no ip timep
Disables TimeP.
Note To change from one TimeP server to another, you must (1) use the no ip timep
command to disable TimeP mode, and then reconfigure TimeP in Manual
mode with the new server IP address.
For example, to select TimeP and configure it for manual operation using a
TimeP server address of 10.28.227.141 and the default poll interval (720
minutes, assuming the TimeP poll interval is already set to the default):
ProCurve(config)# timesync timep
Selects TimeP.
ProCurve(config)# ip timep manual 10.28.227.141
Activates TimeP in Manual mode.
show timep displays the TimeP configuration and also shows
that SNTP is the currently active time synchronization mode.
1
2
3
4
show timep again displays the TimeP configuration and shows that TimeP is
now the currently active time synchronization mode.

Table of Contents

Other manuals for HP ProCurve 2510-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2510-24 and is the answer not in the manual?

HP ProCurve 2510-24 Specifications

General IconGeneral
ModelHP ProCurve 2510-24
Switching Capacity8.8 Gbps
LayerLayer 2
Form FactorRack-mountable
MAC Address Table Size8000 entries
Jumbo Frame SupportYes
PowerAC 120/230 V (50/60 Hz)
ManagementWeb, SNMP, CLI
FeaturesVLAN support, QoS
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Operating Temperature0 to 40 °C
Operating Humidity15% to 95% (non-condensing)
Dimensions44.25 x 17.3 x 4.45 cm

Related product manuals