11-12
Port Trunking
Port Status and Configuration
Listing Static LACP and Dynamic LACP Trunk Data. This command
lists data for only the LACP-configured ports.
Syntax: show lacp
In the following example, ports A1 and A2 have been previously configured
for a static LACP trunk. (For more on “Active”, see table 11-5 on page 11-20.)
Figure 11-6. Example of a Show LACP Listing
Dynamic LACP Standby Links. Dynamic LACP trunking enables you to
configure standby links for a trunk by including more than the maximum
number of allowed ports in a dynamic LACP trunk configuration. When the
maximum number of allowed ports (trunk links) are up, the remaining link(s)
will be held in standby status. If a trunked link that is “Up” fails, it will be
replaced by a standby link, which maintains your intended bandwidth for the
trunk. (See also the “Standby” entry under “Port Status” in table 11-5, "LACP
Port Status Data", on page 11-20.) In the next example, ports A1 through A5
have been configured for the same dynamic LACP trunk, even though a
maximum of four ports are allowed in a trunk by the switch. Notice that one
of the links shows Standby status, while the remaining four links are “Up”.

Table of Contents

Other manuals for HP ProCurve 2510-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2510-24 and is the answer not in the manual?

HP ProCurve 2510-24 Specifications

General IconGeneral
ModelHP ProCurve 2510-24
Switching Capacity8.8 Gbps
LayerLayer 2
Form FactorRack-mountable
MAC Address Table Size8000 entries
Jumbo Frame SupportYes
PowerAC 120/230 V (50/60 Hz)
ManagementWeb, SNMP, CLI
FeaturesVLAN support, QoS
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Operating Temperature0 to 40 °C
Operating Humidity15% to 95% (non-condensing)
Dimensions44.25 x 17.3 x 4.45 cm

Related product manuals