Removal and replacement procedures 26
2.
Close and lock the bezel.
3. Power on the server.
Removing the air baffle
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1. Power down the server (on page 23).
2. Unlock the front bezel.
3. Remove the access panel ("Removing the access panel" on page 24).
CAUTION: Do not detach the cable that connects the battery pack to the cache module.
Detaching the cable causes any unsaved data in the cache module to be lost.

Table of Contents

Other manuals for HP ProLiant ML110 G7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML110 G7 and is the answer not in the manual?

HP ProLiant ML110 G7 Specifications

General IconGeneral
Product TypeServer
Form FactorTower
Processor Sockets1
ChipsetIntel C202
Memory TypeDDR3 UDIMM
Maximum Memory16 GB
Memory Slots4
ProcessorIntel Xeon E3-1200 series
StorageSAS or SATA
Drive Bays4 LFF or 8 SFF
Hard DrivesOptional
Optical DriveOptional
Network ControllerHP NC112i Gigabit Ethernet Adapter (1 port)
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
Storage ControllerHP Dynamic Smart Array B120i