11. Install the air baffle.
12. Install the access panel.
13. Install the bezel.
14. Return the server to an upright position.
15. Connect the power cord to the power source and the server.
16. Power up the server.
Installing a redundant power supply enablement option
For more information about product features, specifications, options, configurations, and compatibility, see the
product QuickSpecs on the Hewlett Packard Enterprise website.
Install the RPS enablement option to improve power efficiency and enable power redundancy. Power
redundancy requires the installation of two power supply modules. This module is a separately purchased
option and is not part of the RPS enablement kit. When the RPS enablement option is installed, the lower
media bay drive will not be available.
Procedure
1. Power down the server.
2. Disconnect the power cord from the power source and the server.
3. Remove the bezel.
4. Place the server on its side with the access panel facing up.
5. Remove the access panel.
6. Remove the air baffle.
7. Disconnect all power supply cables from the system board, drive cages, and devices.
8. Remove all installed devices and any EMI shields from the two media drive bays.
When the RPS enablement is installed, only the upper media drive bay will be available.