Installing a storage controller and FBWC module options
For more information about product features, specifications, options, configurations, and compatibility, see the
product QuickSpecs on the Hewlett Packard Enterprise website.
Procedure
1. Back up all server data.
2. Power down the server.
3. Disconnect the power cord from the power source and the server.
4. Remove the bezel.
5. Place the server on its side with the access panel facing up.
6. Remove the access panel.
7. Remove the air baffle.
8. If you intend to use an FBWC module, install the module on the storage controller.
a. If you are installing a Smart Array P440 Controller, remove the air scoop.
b. Connect the cache module backup power cable to the module.
c. Install the cache module on the storage controller.
Installing a storage controller and FBWC module options 47