Hardware Options Installation 61
6. Configure the device by setting the SCSI ID. The SCSI ID on each device in
the media bays must be manually set to a unique value. Refer to the
documentation provided with the device for instructions on setting the SCSI
ID.
7. Remove all terminating jumpers from third-party SCSI devices.
8. Install the guide screws ("Identifying Guide Screws" on page 58
), if
applicable.
9. Slide the drive into the bay until it clicks into place.
10. Connect the data and power cables to the back of the device.

Table of Contents

Other manuals for HP ProLiant ML350 Generation 4p

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML350 Generation 4p and is the answer not in the manual?

HP ProLiant ML350 Generation 4p Specifications

General IconGeneral
Processor SocketSocket 604
ChipsetIntel E7520
Form FactorTower
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
ProcessorIntel Xeon
MemoryPC2-3200 DDR2 SDRAM
Memory Slots8
StorageSAS or SATA (depending on configuration)
Drive BaysUp to 8 hot-plug drive bays
NetworkEmbedded NC7782 PCI-X Gigabit Server Adapter
Power SupplyRedundant power supply optional
Expansion Slots6 total: 2 PCI-Express, 2 PCI-X