Troubleshooting  93 
•  Install an SSL certificate that Internet Explorer recognizes. 
-or- 
•  Click Continue to this website (not recommended) to ignore the security warning. 
 
Email notifications are not received from an HP-UX 
server 
Action: Add the IP address of the email server to the host file of the computer running the UPS Power 
Protection Agent. 
 
Error LED illuminates or flashes 
Action: Press the Reset button on the management module front panel. If the problem persists, contact an 
authorized service provider. 
The following table lists the error conditions associated with the management module LED. 
 
Test  LED flash error code  Description 
1  Permanently on  DRAM failure 
2  2 flashes  DMA Mem to Mem error 
3  3 flashes  IRQ error 
4  4 flashes  Ethernet error 
5  5 flashes  Serial loop back error 
6  6 flashes  RTC error 
 
 
Error during agent installation 
Symptom: An error occurs while installing the agent on servers with Red Hat 5.0. 
Possible cause: Security enhanced Linux is enabled. 
Action: Run the following commands: 
1.  #chcon –t textrel_shlib_t  ‘/usr/local/DevMan/DMSetup' 
2.  /etc/init.d# ./DevMan setup  
3.  #chcon –t textrel_shlib_t  ‘/usr/local/DevMan/DevManRA' 
 
Event notification messages do not appear on 
console screen 
Action: If you are using SLES 9, upgrade the KDE or use a different desktop, such as GNOME.