3.
After performing the installation or maintenance procedure, slide the server into the rack by pressing
the server rail-release latches.
Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or
removed. Operating the server in this manner results in improper airflow and improper cooling
that can lead to thermal damage.
To remove the component:
1. Power down the server (on page 24).
2. Extend the server from the rack (on page 25).
3. Remove the access panel. If the locking latch is locked, use a T-15 Torx screwdriver to unlock the
latch.
Install the access panel
1. Ensure that the access panel latch is in the open position.