Hardware options installation 66
12.
Install the drive blank in any unused drive bays.
13. Connect each power cord to the server.
14. Connect each power cord to the power source.
15. Power up the server ("Powering up the server" on page 24).
Stand-up SAS controller cable option
The SAS controller cable option is required to enable a PCIe slot-based controller to drive the internal top
bay drives. Otherwise, the drive indicator signaling will not correctly match the accessed drive. The
bottom bay SAS drives cannot be controlled by a PCIe slot-based controller.
CAUTION: To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any system installation. Improper grounding can cause
electrostatic discharge.
To install the component:
1. Power down the server (on page 24).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove the access panel (on page 26).