Extend the server from the rack.
Remove the server from the rack.
6. Remove the front bezel.
7. Remove the access panel:
a. Loosen the access panel thumbscrew.
b. Slide the access panel, and lift it away from the chassis.
Removing the air baffle
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the
amount of time the access panel is open.
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
If the server is in tower mode: Place the server on its side with the access panel facing up.
If the server is in rack mode, do one of the following:
Removal and replacement procedures 33

Table of Contents