3. Install the processor.
4. Install the heatsink.
5. Install the Smart Storage Battery holders.
6. If removed, install the Smart Storage Battery.
7. Install the DIMMs.
8. Install the M.2/dedicated iLO/serial port enablement board.
9. Install the system fan.
10. Install the expansion board.
11. If removed, install the air baffle.
12. Install the front bezel.
13. Install the access panel.
14. Connect all peripheral cables to the server.
15. Connect each power cord to the server.
16. Connect each power cord to the power source.
17. Power up the server.
Re-entering the server serial number and product ID
After you replace the system board, the server serial number and the product ID must be configured:
Procedure
1. Access System Utilities. During POST, press F9.
2. On the System Utilities home screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > Advanced Options > Advanced Service Options.
3. Select the Serial Number field and press Enter.
76 Removal and replacement procedures